Pulsed CCP reduced-order model
Time-dependent state of a capacitively coupled argon discharge in a 1 cm gap under a pulsed or modulated RF drive: electron, ion and metastable densities, electron temperature and potential over position and time. A reduced-order model trained on fluid simulations computes it in your browser, starting from the periodic state at the initial drive.
Drive
The periodic-state and dynamic models are loading.
Mid-gap values, averaged over each RF period
Set the drive and press Run.
Space–time map, averaged over each RF period
t (µs). Vertical: x (mm), driven electrode at 0. Click to show one RF period at that time.
One RF period
time within the period (ns), with the applied voltage on top. Vertical: x (mm).